Maintenance Object Repair Procedures
555-233-123
10-1412 Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. System Technician has busied out the CDR link to out-of-service state. The
CDR link is torn down.
b. Link Retry Test (#215) fails. The Aux Data field contains either the Channel
ID of Data Channels on the TN777 circuit pack (that is, 3 for Channel 01, 4
for Channel 02, 5 for Channel 03, 6 for Channel 04, and 9 for EIA port) or
an Error Code of 99 indicating that no data channels are available for
setting up the link, or an Error Type of 255 indicating an internal system
error. Refer to the preceding ‘‘Procedures for Restoring the CDR Link’’ for
resolution.
Table 10-528. CDR Link Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test cdr-link
primary|secondary sh
18 (a) 0 busy out cdr WARNING OFF release cdr-link
primary|secondary
primary|secondary
25 (b) 0
3 to 6
9
99
255
Link Retry Test
(#215)
MINOR/
WARNING
2
2 Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
OFF test cdr-link
primary|secondary l
513 (c) 0
3 to 6
9
test cdr-link
primary|secondary
1025 (d)
1281 (e)