PROCR (TN2404/TN790 RISC Processor Circuit Pack)
Issue 4 May 2002
10-1431555-233-123
Processor Write Buffer Test (#900)
This test is a nondestructive test. This test verifies that the Write Buffer operates
properly on the Processor circuit pack. Failure of this test is serious. The
Processor circuit pack must be replaced as soon as possible.
Table 10-542. Test #900 Processor Write Buffer Test
Error
Code
Te s t
Result Description/Recommendation
100 ABORT The test did not complete within the allowable time period.
1. Retry the command.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
2500 ABORT Internal system error
1. Retry the command.
FAIL The Processor Write Buffer is not operating correctly.
1. Replace the Processor circuit pack immediately.
NOTE:
If you replace the Processor circuit pack, you
need to obtain a new license file.
PASS The Write Buffer portion of the Processor circuit pack is
operating correctly.
Continued on next page