Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery and detecting the resulting current.
Table 10-544. TEST #35 Battery Feed Test
Error
Code
Te st
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. This result is also
reported for the system’s Music-On-Hold port when it is
off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the
station’s extension. Enter status station extension
to determine the service state of the port. If the port
is in use, wait until the port is idle.
2. Retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test
has been aborted. Use the display port UUCSSpp command
to determine the station extension. Use the status station
command to determine the service state of the port. If the port
is in use, wait until the port is idle.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
1005 ABORT The test was aborted due to a configuration problem. This test
may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the
modem pool member or Music On Hold).