RANL-STA (Remote Analog Line (Station) Port)
Issue 4 May 2002
10-1437555-233-123
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
FAIL The ports battery feed chip is unable to supply sufficient
power to the terminal equipment. This could be a marginal
test, and the terminal equipment may be operating
satisfactorily.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
2. If the test continues to fail, determine whether the
customer is experiencing problems on this line.
Replace the circuit pack only if the customer is
experiencing problems.
PASS The ports battery feed chip is able to provide power to the
station equipment to detect on-/off-hook, but may not be able
to supply power for touch-tones. If touch-tones are inoperative
on this station, then replace the circuit pack because this port
is inoperative.
User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, or by
examining the station.