RANL-STA (Remote Analog Line (Station) Port)
Issue 4 May 2002
10-1439555-233-123
5 FAIL This may be an internal software error. The message waiting
lamp update failed. The translation and ringer updates were not
performed because of this failure.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
7 FAIL The translation update failed. There may be an internal software
error. The ringer update was not performed because of this
failure.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
8 FAIL This does not indicate a hardware problem. There may be an
internal software error. The ringer update failed.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
PASS The software and the port processor have the same status.
User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, or by
examining the station.
Table 10-545. TEST #36 Station Status and Translation Audits and Updates
— Continued
Error
Code
Te st
Result Description/Recommendation
Continued on next page