Maintenance Object Repair Procedures
555-233-123
10-1440 Issue 4 May 2002
Station Present Test (also called Ringing
Application Test) (#48)
This test applies momentary ringing voltage to the terminal equipment and
monitors resulting current flow to determine whether the terminal equipment is
connected to the port. The test may cause some terminal equipment to ring briefly
during daily maintenance. If this ringing disturbs the customer or the terminal
equipment, disable it via the Tests field on the change station form. However,
on some software releases, Test #35 is disabled.
Table 10-546. TEST #48 Station Present Test
Error
Code
Te st
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
UUCSSpp command to determine the station extension. Use
the status station command to determine the service state of
the port. If the service state indicates that the port is in use.
Wait until the port is idle.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test, and the test
was aborted. Use the display port UUCSSpp command to
determine the station extension. Use the status station
command to determine the service state of the port. If the
service state indicates that the port is in use. Wait until the port
is idle.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
1005 ABORT The test was aborted due to a configuration problem. This test
may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the
modem pool member or Music On Hold).
Continued on next page