RANL-STA (Remote Analog Line (Station) Port)
Issue 4 May 2002
10-1441555-233-123
1008 ABORT Could not allocate a ringing circuit. Either all the ringing circuits
are in use or the ringing generator is defective or it is not wired
correctly.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
2. If the test continues to abort, look for RING-GEN
errors in the Error Log. If an ABORT 1008 occurs for
this test on other circuit packs as well, then the
ringing generator may be defective or is not wired
correctly (see errors for RING-GEN). If it does not
occur on other ports, then all four ring phases are in
use.
1018 ABORT The test has been disabled by administration. The default for
the
Test field on the Station form is y. Determine why this
field has been set to
n on this station (this may be due to the
brief ringing disturbance that this test may cause).
1. To enable the test for the particular analog station
being tested, enter change station extension and
set the Test? field on the Station form to y.
Table 10-546. TEST #48 Station Present Test — Continued
Error
Code
Te st
Result Description/Recommendation
Continued on next page