Maintenance Object Repair Procedures
555-233-123
10-1462 Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the
Analog Ring Generator Initialization Test, for example, you may also clear errors
generated from other tests in the testing sequence.
Analog Ring Generator Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/
Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer
to the appropriate test description and follow the recommended procedures.
0 Any Any Any test environment UU
1 Analog Ring Generator
Query Test (#118)
MAJOR ON test environment UU r 3
Multicarrier Cabinet
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1 D = Destructive; ND = Nondestructive
Analog Ring Generator Initialization Test (#117) X X ND
Analog Ring Generator Query Test (#118) X X ND
Battery & Battery Charger Query Test (#5) (a) X X ND
AC Power Query Test (#78) (b) X X ND
Power Unit Query Test (Carrier E) (#127) (c) X X ND
Power Unit Query Test (Carrier D) (#127) (c) X X ND
Power Unit Query Test (Carrier A) (#127) (c) X X ND
Power Unit Query Test (Carrier B) (#127) (c) X X ND
Power Unit Query Test (Carrier C) (#127) (c) X X ND
Emergency Transfer Query Test (#124) (d) X X ND
Cabinet Sensors Query Test (#122) (e) X X ND
External Alarm Lead Query Test (#120) (f) X X ND