SPE-SELEC (SPE Select Switch)
Issue 4 May 2002
10-1513555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. The Warning alarm is upgraded to Major if the error is not resolved in six
hours.
b. Determine the carrier (a or b) by the Port field in the Error or Alarm Log. For
SPE-SELEC, the Port field is 1A (test duplication interface a) or 1B (test
duplication interface b).
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the Duplication Interface Circuit Pack Status Query
Test, for example, you may also clear errors generated from other tests in the
testing sequence.
Table 10-573. SPE Select Switch Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test duplication-interface 1C sh r 1
1 Any SPE Select Query
Test (#278)
WARNING
/ MAJOR
2
2 This error type initially raises a Warning alarm. If this error type persists and alarms are not
downgraded on this MO due to the values of set options, then, after a period of time, a Major alarm
is raised.
OFF test duplication-interface 1C sh r
257 any SPE Select Query
Test (#278)
WARNING
/ MAJOR
2
OFF test duplication-interface 1C sh r 2
Table 10-574. System Technician-Demanded Tests: DUPINT
Order of Investigation Short Test Sequence Long Test Sequence D/ND
1
Active Standby Active Standby
Duplication Interface Circuit Pack Status
Query Test (#315)
XXXXND
Duplication Interface Circuit Pack Sanity
Maze Test (#277)
XXXXND
Continued on next page