Maintenance Object Repair Procedures
555-233-123
10-1548 Issue 4 May 2002
2024
(cont’d.)
ABORT 6. Check the Inter-Carrier Cable to see if it is loose or
disconnected. If so, follow the repair procedures for
reconnecting the Inter-Cabinet Cable described in Chapter 6,
‘‘Reliability Systems: A Maintenance Aid’’.
7. If all problems found in Steps 1, 2, 3, 4, 5, and 6 have now been
repaired, proceed with Step 11. If no problems were found in
Steps 1, 2, 3, 4, 5, and 6, proceed with Step 8.
8. Issue display errors and check to see if Error Type 80 is
logged against STBY-SPE. If so, the problem is the carrier A
Duplication Interface circuit pack. Replace the carrier A
Duplication Interface circuit pack as described in Chapter 6,
‘‘Reliability Systems: A Maintenance Aid’’ and proceed with
Steps 11, 12, and 13.
9. Issue display errors and check to see if an Error Type 81 is
logged against STBY-SPE. If so, the problem is the Standby
SPE Processor circuit pack. Replace the Standby SPE
Processor circuit pack as described in Chapter 6, ‘‘Reliability
Systems: A Maintenance Aid’’ and proceed with Steps 11, 12,
and 13.
Table 10-578. Test Result Error Codes Associated with the Standby SPE — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page