STBY-SPE (Standby SPE)
Issue 4 May 2002
10-1547555-233-123
2022 ABORT The Active SPE successfully put the Standby SPE into Maintenance
Mode but received an incorrect response to a maintenance activity
request that it made to the Standby SPE OR, once in Maintenance
Mode, the Standby SPE sent a request to the Active SPE to have
the Active SPE conduct a portion of a test in the Standby SPEs
behalf, but the Standby SPE received an incorrect response to its
request. The communication path between the Active SPE and the
Standby SPE may have failed. Follow the procedures described for
Error Code 2024 in the STBY-SPE section.
2023 ABORT Internal system error.
2024 ABORT The Standby SPE Maintenance/Tape Processor did not respond to
an Active SPE request to release the Standby SPE Processor to
perform a function; OR the Standby SPE Processor was released
but did not carry out the requested function and/or did not reply to
the request; OR the Standby SPE Processor was released but
cannot run because the Standby SPE Memory is defective. The
communication path between the Active SPE and the Standby SPE
Maintenance/Tape Processor may have failed, or the Standby SPE
Maintenance/Tape Processor may have failed, or the Standby SPE
Processor may have failed.
1. Check for Active SPE Maintenance/Tape Processor errors and
alarms. Refer to PR-MAINT (Maintenance/Tape Processor)
Maintenance documentation and follow the prescribed
procedures.
2. Check for carrier A Duplication Interface circuit pack errors and
alarms. Refer to DUPINT (Duplication Interface Circuit Pack)
Maintenance documentation and follow the prescribed
procedures.
3. Check for Standby SPE Maintenance/Tape Processor errors
and alarms. Refer to PR-MAINT (Maintenance/Tape Processor)
Maintenance documentation and follow the prescribed
procedures.
4. Check for Standby SPE Processor errors and alarms. Refer to
PROCR (80286 Processor Circuit Pack) Maintenance
documentation and follow the prescribed procedures.
5. Check for Standby SPE Memory errors and alarms. Refer to
MEM-BD (Memory circuit pack) Maintenance documentation
and follow the prescribed procedures.
Table 10-578. Test Result Error Codes Associated with the Standby SPE Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page