Maintenance Object Repair Procedures
555-233-123
10-1582 Issue 4 May 2002
Switch Control EPN Maintenance Board Interface
Test (#324)
Loopback messages are sent to the Switch Control through the interface used for
EPN maintenance circuit pack messages. The messages are returned to the SPE
for verification through the same interface.
other FAIL The accuracy of Time of Day clock is not within limits.
1. Run the Short Test Sequence several times to make
sure the error is occurring consistently.
2. Replace the NetPkt or Netcon circuit pack at the
customer’s convenience (Standard system) or right
away (High or Critical Reliability system).
PASS The Time of Day clock on the Switch Control circuit pack is
operating correctly.
Table 10-586. TEST #324 Switch Control EPN Maintenance Board Interface Test
Error
Code
Te s t
Result Description/Recommendation
1005 ABORT The system does not contain an EPN, so this test is not
executed.
1030 ABORT The component on which the test was to be run is on the
Standby SPE. This test may only be run on this component
when it resides on the Active SPE.
1. For recommended maintenance procedure, refer to
ABORT Error Code 1030 in STBY-SPE Maintenance
documentation.
32400 ABORT Test disabled through software patch.
Continued on next page
Table 10-585. TEST #95 Time of Day Clock Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page