SW-CTL (Switch Control)
Issue 4 May 2002
10-1583 555-233-123
2012
32413
32416
32423
32425
ABORT Internal system error
2013
32411
32421
ABORT Could not allocate the necessary system resources to run
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
32414
32417
32424
32427
ABORT The messages failed to return (timed out) and were not
verified.
1. Retry the command at 1-minute intervals a maximum of
five retries.
2. If the test continues to abort and SW-CTL Test #325
passes, there is not a problem, but if SW-CTL Test #325
fails, follow the recommendations for SW-CTL Test #325.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE for a description of these error codes.
Table 10-586. TEST #324 Switch Control EPN Maintenance Board Interface Test
— Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page