TAPE (Tape Unit) [G3iV1.1-286]
Issue 4 May 2002
10-1627 555-233-123
Table 10-602. TEST #692 Tape Block Error Test
Error
Code
Te s t
Result Description/Recommendation
1029 to
2051
ABORT Refer to the STBY-SPE (Standby SPE) Maintenance
documentation for a description of these error codes.
9000’s ABORT Refer to Table A in ‘‘Tape Unit Aux Data/Error Codes Tables’’
and follow the recommended repair strategy for specific Aux
Data.
x0y FAIL “x” indicates the number of uncorrectable block errors
detected by the test [0-5]. “y” indicates the number of
correctable block errors detected by the test [0-5]. Look for
Error Types #1793, #1828, #2049, and #2084 in the Hardware
Error Log and resolve these errors by following the procedures
provided in the “Hardware Error Log Entries and Test to Clear
Values” section.
NOTE:
If the value of “x” is “0,” only the value of “y” is
displayed.
100 FAIL 1. Do the steps below following the directions in the ‘‘Tape
Maintenance and Repair Procedures’’ section.
2. Issue the test tape long command.
3. If the test fails, make sure tape is fully inserted.
4. If the test continues to fail, clean the tape head and retest.
5. If fail, swap tape and retest.
6. If the test still fails, swap tape unit, use original tape and
retest.
PASS No block errors are detected.
Continued on next page