TAPE (Tape Unit) [G3iV1.1-286]
Issue 4 May 2002
10-1629 555-233-123
9024 No tape cartridge in tape drive. 1. Do the steps below following the directions
in the ‘‘Tape Maintenance and Repair
Procedures’’ section.
2. Issue the test tape long command.
3. If the test fails, make sure tape is fully
inserted.
4. If the test continues to fail, clean the tape
head and retest.
5. If fail, swap tape and retest.
6. If the test still fails, swap tape unit, use
original tape and retest.
9025 Tape cartridge is worn, and it is
NOT functional.
1. Do the steps below following the directions
in the ‘‘Tape Maintenance and Repair
Procedures’’ section.
2. Clean the tape head.
3. If still fail, check tape insertion, swap tape if
necessary, and retest.
4. Replace tape unit as a last resort.
9026 Hardware error detected. 1. Do the steps below following the directions
in the ‘‘Tape Maintenance and Repair
Procedures’’ section.
2. Issue test tape long dispatch with tape
unit.
3. If the test fails, make sure tape is fully
inserted.
4. If the test continues to fail, clean the tape
head. Use original tape and retest.
5. If the test still fails, swap tape unit, use
original tape and retest.
NOTE:
It is very important that hardware
problems are resolved before using
backup tape.
6. If fails again, swap tape and retest.
9027 The test failed because the
software could not access the
tape hardware.
Table 10-603. Table A: Tape Unit Aux Data Table — Continued
Aux Data/
Error Codes Explanation Strategy
Continued on next page