TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
Issue 4 May 2002
10-1675 555-233-123
Table 10-615. TEST #619 BRI Port Local TDM Loop Around
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT The system resources required to run this test are not
available. The port may be busy with a valid call. Use display
port PCSSpp to determine the trunk group/member number
of the port. Use status bri-port PCSSpp to determine the
service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests.
Wait until the port is idle before retesting.
1. If the port is idle, then retry the command at 1-minute
intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS to diagnose any active TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log and if present,
refer to TTR-LEV.
2. Look for TONE-PT errors in the Error Log and if present,
refer to TONE-PT.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use status
trunk for the trunks associated with this port and determine
when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005 ABORT This test is not valid for this type of translation. Ports
administered as ASAI or ADJK cannot run this test because
the B channels associated with the port are not used by ASAI
or AT&T Adjunct Links. This is a normal condition.