TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
Issue 4 May 2002
10-1681 555-233-123
1 FAIL Received a status of Level 1 Pending Activation. U interface
down indicating a problem with a connection between the
switch and the NT1, a 2- to 4-wire converter that is used to
connect 4-wire terminals to a 2-wire TN2198 or TN2185
circuit pack.
1. Verify that the connections between the switch and the
NT1 are good. Verify that the NT1 has power.
2. Execute the test port PCSSpp command and review the
results of the Level 1 Status Inquiry Test to verify the
repair. If this test still fails, proceed to Step 3.
3. Follow the manufacturers repair procedures for the NT1.
Then execute the test port PCSSpp command and
review the results of the Level 1 Status Inquiry Test to
verify repair.
2 FAIL Received a status of Level 1 Pending Activation. U interface
up, S/T interface down, which indicates a problem with the
NT1 or the wiring between the NT1 and the BRI endpoint (S/T
interface).
1. Execute the test port PCSSpp command and review the
results of the Level 1 Status Inquiry test to verify the
repair. If this test still fails, proceed to Step 2.
2. Follow the manufacturer-recommended repair
procedures for the NT1. Then execute the test port
PCSSpp command and review the results of the Level 1
Status Inquiry test to verify repair.
Table 10-618. TEST #1242 Level 1 Status Inquiry Continued