Maintenance Object Repair Procedures
555-233-123
10-1688 Issue 4 May 2002
Service State Audit (#256)
This test is non-destructive.
This test performs a service state audit on an ISDN B-Channel. The test passes if
Call Processing informs Maintenance that the Restart message was transmitted
successfully, or if the B-Channel was busy and could not send the message.
The test fails if the board is not inserted or translated properly, or if a reply is not
received within a certain amount of time.
The test aborts if the signaling link is disconnected, if a message is already
outstanding, or if the necessary resources could not be allocated.
To investigate the service state of the TN2185 ISDN Trunk-Side BRI Channel,
issue the status trunk trunk-group/trunk-member command.
8 FAIL The signaling link is down.
1. Consult the procedures for the TBRI-PT maintenance
object.
9 FAIL The port is out of service.
1. Return the port to an in-service state.
PASS The signaling link is connected and operating normally.
Table 10-621. TEST #1251 Signaling Link State Test Continued
Error
Code
Te s t
Result Description/Recommendation