TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 4 May 2002
10-1689 555-233-123
Table 10-622. TEST #256 Service State Audit Test
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
The port may be on a valid call. Use status trunk to determine
when trunk is available for testing.
1. Check the results of Test #1251 (Signaling Link State
Check).
1018 ABORT The test is disabled.
1. Enable maintenance by entering y in the
Maintenance
Tests?
field on page 2 of the change trunk-group
form.
1113 ABORT The signaling link has failed, so the system cannot send any
messages on behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State Test
).
1114 ABORT The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1116 ABORT The trunk is not in a service state which is appropriate for
running the test. This test is only performed in the OOS/FE
state.
1117 ABORT A service state audit message is outstanding.
1. Wait two minutes and then try again.
Continued on next page