Maintenance Object Repair Procedures
555-233-123
10-1774 Issue 4 May 2002
Table 10-651. TEST #74 Tie Trunk EPF Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run the
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1 ABORT Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available.
The trunk may be busy with a valid call. Use display trunk xx
to determine trunk group/member number of the port. Use
status trunk to determine the service state of the port. If the
service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is
idle before retesting.
1. If the port status is active, but the port is not in use (no
calls), then check the Error Log for Error Type 1025 (see
Error Log table for description of this error and required
actions). The port may be locked up. The far-end PBX
may not be releasing.
2. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test
has been aborted. Use display trunk xx to determine the
trunk group/member number of the port. Use status trunk to
determine the service state of the port. If the service state
indicates that the port is in use, the port is unavailable for
certain tests. (Refer to the Status Commands section in
Chapter 8, ‘‘Maintenance Commands and Trouble-Clearing
Aids’’ for a full description of all possible states.) You must
wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1005 ABORT This test is not valid for this trunk translation. Must be a
Type-1 standard trunk for this test to run.
1. Check trunk configuration. If it is not a Type-1 standard
trunk, this abort message should be ignored.