TIE-TRK (Tie Trunk)
Issue 4 May 2002
10-1775 555-233-123
1014 ABORT The test was aborted because the circuit pack has not been
inserted into the system.
1. Use list configuration board to make sure the circuit
pack is inserted in the carrier.
2. If the board is not inserted, make sure the circuit pack is
inserted in the carrier and fully seated.
3. If the test continues to fail, escalate problem.
1040 ABORT This test is not performed for trunk ports administered as
“access endpoints.”
1. Verify this port is an access endpoint by using the display
port command.
2. If the port has been administered as an access endpoint,
this test should abort.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run the
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1 FAIL The E lead test failed due to an on-board port problem.
1. Replace the circuit pack.
2 FAIL The M lead test failed. The EPF has experienced an
overcurrent condition, perhaps due to the external M lead.
1. To make sure the problem is on-board, disconnect the
facility from the pack and retry the test.
2. If the test fails, replace the circuit pack. Otherwise, check
the external wiring toward the far-end PBX.
Table 10-651. TEST #74 Tie Trunk EPF Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page