TIE-TRK (Tie Trunk)
Issue 4 May 2002
10-1777 555-233-123
Table 10-652. TEST #844-848 Transmission Test
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. Use display port
PCSSpp to determine the trunk group/member number of the
port. Use the “status trunk” command to determine the service
state of the port. If the service state indicates that the port is in
use, then the port unavailable for this test. (Refer to the
“Status Commands” section in Chapter 8, ‘‘Maintenance
Commands and Trouble-Clearing Aids’’ for a full description of
all possible states.) You must wait until the port is idle before
retesting.
1. If the port status is idle, then retry the command at
1-minute intervals for a maximum of 5 retries.
1001 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals for a maximum
of 5 retries.
1002 ABORT The system could not allocate timeslots for the test. The
system may be under heavy traffic conditions or it may have
timeslots out of service due to TDM bus errors. Refer to TDM
Bus Maintenance to diagnose any active TDM bus errors.
1. If system has no TDM bus errors and is not handling
heavy traffic, repeat test at 1-minute intervals for a
maximum of 5 retries.
1004 ABORT The port has been seized by a user for a valid call. Use status
trunk to determine when the port is available for testing.
1. Retry the command at 1-minute intervals for a maximum
of 5 retries.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005 ABORT Trunk has been administered as incoming-only; transmission
tests can only be run on outgoing trunks.
1115 ABORT The near end test line on the TN771 circuit pack could not be
allocated.
1. Verify that the TN771 circuit pack is in service and that
port 1 is administered and in service with the status port
command.
2. retry the command at 1-minute intervals for a maximum of
5 retries.
Continued on next page