Maintenance Object Repair Procedures
555-233-123
10-1780 Issue 4 May 2002
2053 ABORT The test call could not be established, but no information on
why is available.
1. Retry the command at 1-minute intervals for a maximum
of 5 retries.
2056 ABORT An error occurred while trying to obtain results from the TN771
circuit pack.
1. Test the TN771 circuit packs.
FAIL Measured transmission performance was in the unacceptable
range as administered on the trunk group form. Retrieve a
measurement report via list testcalls. Make sure that ATMS
thresholds are set properly on page 4 of the trunk group form.
Besides the facility, test failures can be caused by faulty test
lines or switch paths. If the measurements point to a facility
problem, report the results to the trunk vendor.
8000 FAIL Measured transmission performance was in the marginal
range as administered on the trunk group form. This generally
means that the trunk is usable but has an undesirable amount
of noise or loss. If the user does not report unacceptable
effects, it may not be necessary to take any action. Retrieve a
measurement report via list testcalls. Make sure that ATMS
thresholds are set properly on page 4 of the trunk group form.
Table 10-652. TEST #844-848 Transmission Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page