TIE-TRK (Tie Trunk)
Issue 4 May 2002
10-1779 555-233-123
1921 ABORT No data returned from far end.
1. The problem is with the far end system; a technician at
the far end should test the test line (TN771 or ADFTC).
1922 ABORT Steady, unidentifiable tone from far end
1. See actions for error code 1905.
1923 ABORT Broadband energy detected from far end (such as voice or
announcement).
1. See actions for error code 1905.
1924 ABORT No test tone from far end
1. See actions for error code 1905.
1938 ABORT Near-end self test failed.
1. Test the TN771 circuit packs.
1939 ABORT Loss self check at 0dBm at 1004 Hz failed.
1. Test the TN771 circuit packs.
1940 ABORT Far end noise self check failed.
1. The problem is with the far end system; a technician at
the far end should test the test line (TN771 or ADFTC).
1941 ABORT High frequency singing return loss self check failed.
1942 ABORT Echo return loss self check failed.
1943 ABORT Singing return loss self check failed.
1944 ABORT Loss self check at -16 dBm at 1004 Hz failed.
1945 ABORT Loss self check at -16 dBm at 404 Hz failed.
1946 ABORT Loss self check at -16 dBm at 2804 Hz failed.
1947 ABORT Noise with tone self check failed.
1. Test the TN771 circuit packs.
2000 ABORT The test timed out while waiting for a response from the
TN771 circuit pack.
1. Retry the command at 1-minute intervals for a maximum
of 5 retries.
2012 ABORT An internal software error occurred.
1. Retry the command at 1-minute intervals for a maximum
of 5 retries.
Table 10-652. TEST #844-848 Transmission Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page