Maintenance Object Repair Procedures
555-233-123
10-1808 Issue 4 May 2002
Table 10-657. TEST #40 Tone Generator Transmission Test
Error
Code
Te s t
Result Description/Recommendation
None ABORT The system was not able to allocate all the resources needed
for this test or there was an Internal System Error.
1 ABORT The system could not allocate all the resources needed to test
the DTMF tones.
1001 ABORT The system was not able to put the tone generation facility in
the appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test
connection. This can happen when the system is heavily
loaded. If the system is not heavily loaded, then test the TDM
Bus via test tdm port-network PN# . Refer to TDM-BUS
section for details.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, follow normal escalation
procedures.
1003 ABORT The system could not allocate a tone receiver for the test
connection. This can happen when the system is heavily
loaded or there is not a Tone Detector circuit pack in the port
network where this test is being executed.
1. Make sure there is a Tone Detector circuit pack in the
same port network.
2. If a Tone Detector circuit pack is missing, install one in the
same port network.
3. Allow approximately 1 minute for Tone Detector
maintenance to run on the newly inserted Tone Detector
circuit pack.
4. Retry the command at 1-minute intervals a maximum of 5
times.
5. If the test continues to abort, follow normal escalation
procedures.
Continued on next page