Maintenance Object Repair Procedures
555-233-123
10-1812 Issue 4 May 2002
2 FAIL The system requires TN2182 tone-clocks to support the
currently administered country-options tone generation
parameters.
1. Check the administration on the system-parameters
country-option form. Specifically, the Base Tone
Generation Set on page 1 and any custom tone
administration beginning on page 2.
2. Replace existing tone-clock circuit packs with TN2182s.
PASS The tone generation facility has been successfully refreshed
with its time-slot translation and system administration is
consistent with this type of tone-clock.
1. Display the Hardware Error Log via display errors to
make sure this circuit pack did not generate new errors.
2. If errors persist, follow normal escalation procedures.
Table 10-658. TEST #41 Tone Generator Update/Audit Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page