Maintenance Object Repair Procedures
555-233-123
10-1822 Issue 4 May 2002
b. The port field in the error log contains the signaling group number for
TSC-ADM errors.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the TSC
Heartbeat Inquiry Test, for example, you may also clear errors generated from
other tests in the testing sequence.
TSC Heartbeat Inquiry Test(#604)
This test can be invoked by system technician personnel for any ADMTSC
administered in the switch. The following table indicates the possible error
conditions that might be encountered when the test is invoked. Most of the error
conditions do not log an error, but switched services may take some type of
recovery action in certain instances.
This test sends a USER INFORMATION TSC heartbeat message inquiry across
an Administered TSC to determine if the far-end can respond to a USER
INFORMATION TSC heartbeat message.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive; ND = Nondestructive
TSC Heartbeat Inquiry Test (#604) ND
Table 10-663. TEST #604 TSC Heartbeat Inquiry Test
Error
Code
Te s t
Result Description/Recommendation
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Reissue the test tsc-administered command at
1-minute intervals a maximum of 5 times.
1005 ABORT The Administered TSC does not exist.
1. Display the administration for the Administered TSC.
2. If an Administered TSC is exists, reissue the test
tsc-administered command.
3. If the test continues to abort, escalate problem.
Continued on next page