VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 4 May 2002
10-1951 555-233-123
Receive FIFO Overflow Error Counter Test (#596)
This test is non-destructive. When the VAL circuit pack detects packet bus buffer
overflow, it increments the error on the FIFO Overflow error counter. This test
reads and clears the counter.
If errors are: Then they can be due to:
Occasional Statistical buffer sizing
Table 10-696. TEST #596 Receive FIFO Overflow Error Counter Test
Error
Code
Te s t
Result Description/Recommendation
2000 ABORT Did not receive circuit pack test response within the allowable
time period.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board
UUCSS).
If the problem persists, replace the circuit pack.
2100 ABORT Could not allocate the necessary system resources to run test.
2500 ABORT Internal system error.
Retry the command at 1-minute intervals, up to 5 times.
If the problem persists, escalate the problem.
1-10 FAIL Circuit pack detects overflow errors. The error code indicates the
value of the on-board error counter.
Retry the command at 1-minute intervals, up to 5 times.
If the test continues to fail, execute the Packet Interface Test
(#598) (test board UUCSS).
If Packet Interface Test (#598) fails, see repair procedures for
Test (#598).
PASS Circuit pack detects no errors.