Maintenance Object Repair Procedures
555-233-123
10-1954 Issue 4 May 2002
Congestion Query Test (#600)
This non-destructive test queries the number of used buffers to determine if the
VAL circuit pack is congested.
Normal call handling resumes when the VAL circuit pack has recovered from
congestion.
FAIL Circuit pack has detected a failure of the Packet Interface Test
(#598).
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board
UUCSS).
If the test continues to fail, replace the circuit pack.
PASS The Packet Interface Test (#598) passed.
If: Then:
Used buffers are, or are nearly,
exhausted,
The test fails.
The test fails, The switch alarms, and announcements can fail.
Table 10-699. TEST #600 Congestion Query Test
Error
Code
Te s t
Result Description/Recommendation
2000 ABORT Did not receive circuit pack test response within the allowable
time period.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board
UUCSS).
If the problem persists, replace the circuit pack.
Continued on next page
Table 10-698. TEST #598 Packet Interface Test Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page