Maintenance Object Repair Procedures
555-233-123
10-1956 Issue 4 May 2002
Link Status Test (#601)
This non-destructive test determines the state of the call control signaling link for
VALs. If the signaling link is physically connected, the test sends a test frame over
the link and checks for a response. The test passes only if both the signaling link
is connected and the test frame is successfully transmitted.
A failure can indicate a problem with:
■ this circuit pack.
■ the packet bus.
■ the packet interface circuit pack.
Table 10-700. TEST #601 Link Status Test
Error
Code
Test
Result Description/Recommendation
1125 ABORT RSCL link or VAL board not in service.
Release the board.
Repeat the test.
Escalate if the problem persists.
2012 ABORT Could not allocate the necessary system resources to run this
test.
2100 ABORT Internal system error.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, escalate the problem.
Continued on next page