VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 4 May 2002
10-1957 555-233-123
Configurations
The following figure shows the configuration options for the TN2501AP (VAL)
circuit pack within a system.
2 FAIL The RSCL control link disconnected.
Retry command at 1-minute intervals, up to 5 times.
If the test continues to fail, execute the Packet Interface Test
(#598) (test board UUCSS) to see if the problem is in the circuit
pack.
If the Packet Interface Test (#598) fails, refer to Packet Interface
Test repair procedures.
If the Packet Interface Test (#598) passes, refer to Packet
Control Circuit Pack and Packet Bus repair procedures.
3 FAIL Received no response to RSCL control link test frame.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board
UUCSS).
If test continues to fail, replace the circuit pack.
PASS RSCL control link connected.
Table 10-700. TEST #601 Link Status Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page