Maintenance Object Repair Procedures
555-233-123
10-1968 Issue 4 May 2002
SCOTCH Synchronous Looparound Test (#1275)
This test is destructive.
This test verifies the circuit in the data path of a VAL announcement port call. This
test fails if the data transmitted on the port does not match the data received in the
looparound mode. Failure of this test indicates a port hardware fault on the circuit
pack.
This test aborts if calls are using the port, or if the VAL link associated with the
port is connected. To avoid this, at the SAT type busyout port UUCSSpp, which
tears down all calls and links using the port.
Table 10-706. TEST #1275 SCOTCH Synchronous Looparound Test
Error
Code
Tes t
Result Description/Recommendation
1000 ABORT The port is in use.
Retry the command when the port is idle. You can force the port
to the idle state with the busyout port UUCSS command.
This command is destructive, tearing down all calls and links
using the port.
1002 ABORT No TDM bus timeslots available for the test.
Retry the command at 1-minute intervals, up to 5 times.
Escalate if the problem persists.
1963 ABORT The port is in use.
Retry the command when the port is idle. You can force the port
to the idle state with the busyout port UUCSS command.
This command is destructive, tearing down all calls and links
using the port.
2000 ABORT Did not receive circuit pack test response within the allowable
time period.
If this problem persists, reset the circuit pack (busyout board
UUCSS, reset board UUCSS, and release board UUCSS).
If the problem persists, replace the circuit pack.
2012 ABORT Internal system error.
Retry the command at 1-minute intervals, up to 3 times.
Escalate if the problem persists.