VC-DSPPT
Issue 4 May 2002
10-1981 555-233-123
Table 10-711. TEST #1105 VC-DSP Port DSP Loopback Test
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available, or
the port is busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1002 ABORT The system could not allocate time slots for the test, the traffic
load on the system is very high, or time slots are out-of-service
due to TDM-BUS errors. Refer to “TDM-BUS” to diagnose
TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling
heavy traffic, repeat the test at 1-minute intervals a
maximum of 5 times.
1003 ABORT The system could not allocate a Tone Detector for the test, the
system is oversized for the number of Tone Detectors present,
or some Tone Detectors are out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use the
status station command for the station associated with this
port and determine if the port is available for testing
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000 ABORT Response to the test request was not received from the VC-BD
circuit pack within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack if the
other ports are not in use by using the busyout port
PCSSpp and reset port PCSSpp commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page