XXX-BD (Common Port Circuit Pack)
Issue 4 May 2002
10-2013 555-233-123
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack.
This test is executed as part of the long test sequence only for the Tone-Clock
circuit pack and DS1 interface circuit packs. All other common circuit packs can
Table 10-723. TEST #52 Control Channel Loop Around Test
Error
Code Test Result Description/Recommendation
none or
2100
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of
5 times.
FAIL The test failed because the circuit pack failed to return the
circuit pack code or vintage.
1. Retry the command for a maximum of 5 times.
2. If the test still fails, issue the busyout board, reset
board, and release busy board commands, and then
retest.
3. If the problem continues, replace the circuit pack.
4. Run the test again.
PASS Communication with this circuit pack is successful.
EXTRA BD This result should only appear for the TN771B or TN771C
Maintenance/Test circuit pack. More than one circuit pack
has been installed in this port network. Remove this circuit
pack.
any NO BOARD This is normal if the test is being done when (a) the circuit
pack is not physically in the system or (b) the system is
booting up. Otherwise, there is some inconsistency
between the physical configuration and the data kept in the
system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. ) Retry the command at 1-minute intervals for a
maximum of 5 times.
Continued on next page