Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-150 Issue 4 May 2002
test tsc-administered
Help Messages
If the system technician presses HELP after entering test tsc-administered the
following message appears:
Enter group # (1-8) or group #, [/tsc index (1-64)],
[repeat (1-100)], [schedule]
Error Messages
If the format for the specified signaling group or the signaling group and TSC is
incorrect, the following message appears:
Format invalid
If the specified signaling group number is out of range, the following message
appears:
Signaling group invalid
If the specified signaling group is not administered, the following message
appears:
No signaling group assigned
If the specified signaling group has no TSC assigned or the specified TSC is
unadministered, the following message appears:
No TSC assigned
If the specified TSC number is out of range, the following message appears:
Tsc index invalid
If the software data cannot be sent to the SAT, the following message appears:
Error encountered, cant complete request
If no tests can be found for the associated MO, the following message appears:
No tests for this MO
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
login id:command has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy;
Press CANCEL to clear, and then resubmit