Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-414 Issue 4 May 2002
!
WARNING:
Executing a clear with short option may not clear all alarms, even if all tests
pass.
!
WARNING:
Since the “clear long” options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
Feature Interactions
With the enhancement of multiple maintenance users, there may be a possibility
of two users attempting to test the same physical hardware (for example, one
using the test alarms command and another using the test board command). If
this command attempts to test a board that is currently being tested by another
user, a error message displays.
Options form
After entering test alarms, an options form for alarm selection appears.
test alarms repeat 1
HARDWARE TEST ALARM QUERY
The following options control which alarms will be tested.
ALARM TYPES
Major? y_ Minor? y_ Warning? y_
REPORT PERIOD
Interval: m_ From: __/__/__:__ To: __/__/__:__
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet: __
Port Network: __
Board Number: ____
Port: ______
Category: ________
Extension: _____
Trunk ( group/member ): __/__