test alarms
Issue 4 May 2002
8-415555-233-123
Field descriptions (Hardware Test Alarm Query)
Alarm Types
The type of alarm to be tested: put y or n in the field(s) to
selects one or a combination of alarms.
Interval
Tests alarms for the last hour (h), last day (d), last week (w) or
all (a) [default].
From
Test alarm from the specified time specified (mm/dd/hh/mm). If
no
from date is entered, then no checking is done and the
alarms active since a month prior to the current time are
reported.
To
Test alarms associated with records to the specified time
specified (mm/dd/hh/mm). If no
to date is entered, any alarm
active after the
from date is selected.
Equipment
Type
The technician can choose between five different equipment
types. If there is no input to any of these fields, the system
defaults to all the equipment. The user can select one of the
following fields:
Cabinet: tests alarms associated with a particular
cabinet (1-3).
Port Network: tests all alarms associated with a
particular port network (1-3).
Board Number: tests all alarms associated with a
particular circuit pack (PCss, default cabinet = 1).
Port: tests all alarms associated with a particular port on a
circuit pack (PCsspp, default cabinet = 1).
Category: Alarms for a particular equipment category
Extension: Alarms associated with an extension number
Trunk (group/member): tests all alarms associated with a
particular trunk group or trunk group member, XX/YY,
where the group identifier tests all alarms associated with a
trunk group (XX/__), and the group identifier and member
identifier are both entered to test all alarms associated with
a specific trunk group member (XX/YY).