ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 4 May 2002
10-41 555-233-123
Loop Around Test (#161)
This test is designed to check the on-board transmission capabilities of the NPE
on the analog port.
Table 10-16. TEST #161 Loop Around Test
Error
Code
Tes t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources for this test.
Try (a).
1000 ABORT System resources required to run this test are not available. The
port may be busy with a valid call.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port. If the port is in use, wait until it is idle before
testing.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system
may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors. Refer to “TDM-BUS” to
diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, retry the command at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has
been aborted.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port. If the port is in use, wait until the port is idle
before testing.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
Continued on next page