Maintenance Object Repair Procedures
555-233-123
10-42 Issue 4 May 2002
1018 ABORT Test disabled by administration. To enable the test for the
particular analog station being tested, enter the change station
<extension> command and change the Test? field on the
Station Form from
n to y.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL The reflective Loop Around Test failed. This causes noisy or
unreliable connections or other users calling this port may hear
an echo.
1. Replace the circuit pack.
PASS The port is able to provide an analog transmission path to the
station equipment. User-reported troubles on this port should be
investigated by using other port tests, by examining station
wiring, or by examining the station.
Table 10-16. TEST #161 Loop Around Test — Continued