Loading...
ANL-24-L (24-Port Analog Line)
Issue 4 May 2002
10-45 555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: These are in-line errors and can only be resolved over time.
40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5th incoming call will cause an inline error from
the board.
Table 10-17. 24-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and Updates
Test (#36)
18 0 busy-out station
extension
WRN ON release station
<extension>
130(c) None WRN ON test port PCSSpp sh
257(d) 40973 none
513(e) Station Present
Test (#48)
WRN OFF test port PCSSpp sh r 2
769 Battery Feed Test
(#35)
MIN/
WRN
2
2 Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON test port PCSSpp sh r 2
1025 Looparound Test
(#161)
MIN/
WRN
2
ON test port PCSSpp l r 2
1281 Conference Test
(#7)
MIN/
WRN
2
ON test port PCSSpp l r 2
1537 NPE Crosstalk Test
(#6)
MIN/
WRN
2
ON test port PCSSpp l r 2
Continued on next page