ANL-24-L (24-Port Analog Line)
Issue 4 May 2002
10-53 555-233-123
1392 ABORT This port is currently a TTI port and the test will not execute on
it.
1. Verify that the port is a TTI port using either the display
port command (the display shows that the port is a TTI
port) or the list config command (the display shows a t
for the port).
2. If the port is not a TTI port, escalate the problem. If both
commands indicate that the port is a TTI port, the abort is
correct for the test, and no action is necessary.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL The port’s battery feed chip is unable to supply sufficient power
to the terminal equipment. This could be a marginal test, and
the terminal equipment may be operating satisfactorily.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, determine whether the
customer is experiencing problems on this line. If so,
replace the circuit pack.
Table 10-20. TEST #35 Battery Feed Test — Continued
Error
Code
Te s t
Result
Description/Recommendation
Continued on next page