Maintenance Object Repair Procedures
555-233-123
10-52 Issue 4 May 2002
Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery and detecting the resulting current.
For the TN746B, Test #35 does not actually run and instead always returns PASS.
Test #35 operates in the normal manner for TN746.
Table 10-20. TEST #35 Battery Feed Test
Error
Code
Te s t
Result
Description/Recommendation
ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. This result is also
reported for the systems Music-On-Hold port when it is
off-hook, which it usually is.
1004 ABORT The port was seized by a valid call during the test. The test has
been aborted.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port.
3. If the port is in use, wait until the port is idle and retry the
command at 1-minute intervals a maximum of 5 times.
1005 ABORT The test was aborted due to a configuration problem. This test
may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the
modem pool member or Music On Hold).
1018 ABORT The test has been disabled via administration. The default for
the
Test field on the station form is y. Determine why this
field has been set to
n on this station (this may be due to the
ringing application test 48, that can be customer or terminal
disturbing).
1. To enable the test for a particular station being tested,
enter change station extension and set the
Test? field
on the station from
n to y.