Maintenance Object Repair Procedures
555-233-123
10-56 Issue 4 May 2002
1 FAIL This does not indicate a hardware problem. The switchhook
audit failed. The other updates were not performed because of
this failure. This may occur when the audit is performed at the
same time the terminal equipment goes off-hook.
1. Use the status station command to determine when the
port is available and retry the command at 1-minute intervals
a maximum of 5 times.
5 FAIL This may be an internal software error. The message waiting
lamp update failed. The translation and ringer updates were not
performed because of this failure.
7 FAIL The translation update failed. There may be an internal software
error. The ringer update was not performed because of this
failure.
8 FAIL This does not indicate a hardware problem. There may be an
internal software error. The ringer update failed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS The software and the port processor have the same status.
User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, or by
examining the station.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Check to ensure the board translations are correct. Use the
list config command and resolve problems.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the port.
If this is not the case, check to ensure that there is a valid
board inserted.
Table 10-21. Test #36 Station Status and Translation Audits and Updates — Continued
Error
Code
Te s t
Result
Description/Recommendation
Continued on next page