Maintenance Object Repair Procedures
555-233-123
10-82 Issue 4 May 2002
Table 10-30. TEST #161 Loop Around Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the station extension. Use
the status station command to determine the service state of
the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM Bus) Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to the TTR-LEV (TTR Level) Maintenance
documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to the TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
Continued on next page