ANL-16-L (16-Port Neon Analog Line)
Issue 4 May 2002
10-83 555-233-123
1004 ABORT The port was seized by a valid call during the test. The test has
been aborted. Use the display port PCSSpp command to
determine the station extension. Use the status station
command to determine the service state of the port. If the
service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is idle
before retesting.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005 ABORT The test is not run because the port is administered as either
an External Alert or Announcement port.
1018 ABORT The test has been disabled via administration. The default for
the ’Test’ field on the ’Station’ form is ’y’; thus, you may want to
determine why this field has been set to ’n’ on this station (this
may be due to the ringing application test 48, which can be
customer or terminal disturbing).
1. To enable the test for the particular analog station being
tested, enter change station extension and set the
‘Test ?’ field on the station from 'n' to 'y.'
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-30. TEST #161 Loop Around Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page