Maintenance Object Repair Procedures
555-233-123
10-102 Issue 4 May 2002
Table 10-35. TEST #47 Loop Around and Conference Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
7 ABORT The port was seized by a user for a valid call.
1. Enter display port PCSSpp to determine the station’s
extension. Enter status station extension to determine
the service state of the port. If the port is in use, it will be
unavailable for certain tests. Wait until the port is idle
before retesting.
2. If the port is idle, retry the command at 1-minute intervals
up to 5 times.
1000 ABORT System resources required to run this test were not available.
The port may be busy with a valid call. (This could be a
Music-on-Hold port.)
1. Enter display port PCSSpp to determine the station’s
extension. Enter status station extension to determine
the service state of the port. If the port is in use, it will be
unavailable for certain tests. Wait until the port is idle
before retesting.
2. If the port is idle, retry the command at 1-minute intervals
up to 5 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
“TDM-BUS (TDM Bus)” Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
Continued on next page