Maintenance Object Repair Procedures
555-233-123
10-112 Issue 4 May 2002
Error log entries and test to clear values
Notes:
a. Error Type 1: these are in-line errors and can only be resolved over time.
■ Aux Data 40960 indicates that too many simultaneous incoming
ringing attempts were made on this board. Only 4 ports on a board
may ring simultaneously. A 5th incoming call will cause an inline
error from the board.
■ Aux Data 40975 indicates that the terminal equipment was on-hook
when ring-tip was detected during ringing. This usually indicates a
failure in the terminal equipment or the type of terminal has a low
ringer impedance.
Table 10-37. Analog line error log entries
Error
Type
Aux
Data
Associated
Tes t
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and
Updates Test
(#36)
18 0 busy station
extension
WRN ON release station extension
130(c) None WRN ON test port UUCSSpp sh
257(d) 40973 none
513(e) Station
Present Test
(#48)
WRN OFF test port UUCSSpp sh r 2
769 Battery Feed
Test (#35)
MIN/
WRN
2
2 Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON test port UUCSSpp sh r 2
1025 Looparound
Test (#161)
MIN/
WRN
2
ON test port UUCSSpp l r 2
1281 Conference
Test (#7)
MIN/
WRN
2
ON test port UUCSSpp l r 2
1537 NPE
Crosstalk
Test (#6)
MIN/
WRN
2
ON test port UUCSSpp l r 2