AN-LN-PT (Analog Line Port)
Issue 4 May 2002
10-117 555-233-123
Any FAIL This test can fail due to on-board or off-board problems.
Off-board problems include TDM-BUS faults, EXP-PN and
EXP-INTF faults, and faults associated with the tone
detectors/tone generators. Clear all off-board problems before
replacing the board.
1. A TDM-BUS problem is usually the result of a faulty board
connection to the backplane, or bent pins on the
backplane. Resolve any TDM-BUS errors in the error log.
2. Resolve any EXP-PN and/or EXP-INTF errors in the error
log.
3. Resolve any TONE-BD and/or TONE-PT errors in the
error log.
4. Test the board when the faults from Steps 1, 2, and 3 are
cleared. Replace the board only if the test fails.
PASS The port is correctly using its allocated time slots. Investigate
user-reported troubles on this port by running other port tests,
by examining station wiring, or by inspecting the station.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This result could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to make sure that the board translations are
correct. Use the list configuration command, and
resolve any problems.
2. If the board is correctly inserted, issue the busy board
UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This
re-establishes the link between the internal ID and the
port.
6. If this is not the case, check to make sure that a valid
board is inserted.
Table 10-38. TEST #6 NPE Crosstalk Test Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page