Maintenance Object Repair Procedures
555-233-123
10-118 Issue 4 May 2002
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested correctly performs
the conferencing function.
Table 10-39. TEST #7 Conference Circuit Test
Error
Code
Tes t
Result Description/Recommendation
ABORT Necessary system resources could not be allocated to run this
test.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources are unavailable. The port may be busy with
a valid call. This result is also reported for the systems
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the stations
extension.
2. Enter status station extension to determine the service
state of the port.
3. If the port is in use, wait until the port is idle. Retry the
command at 1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine
the station extension.
2. Use the status station extension command to determine
the service state of the port.
3. If the port is in use, wait until the port is idle before testing.
Retry the command at 1-minute intervals no more than 5
times.
4. If the test continues to abort, escalate the problem.
1005 ABORT This test was aborted due to a configuration problem. The test
is not applicable for this type of analog port. This error can be
ignored.
1018 ABORT Administration has disabled the test. The default for the
Test? field on the station form is y. Determine why this field
has been set to n on this station (this may be due to the
ringing application Test #48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested,
enter change station extension.
2. Change the Test? field on the station form to y.
Continued on next page