AN-LN-PT (Analog Line Port)
Issue 4 May 2002
10-119 555-233-123
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Resolve any TONE-PT errors in the error log.
2. If there are no TONE-PT errors, retry the command at
1-minute intervals no more than 5 times.
3. If the test continues to abort, escalate the problem.
Any FAIL The NPE of the tested port did not conference the tones
correctly. This causes noisy and unreliable connections.
1. Issue the display port UUCSSpp and the status station
extension commands to determine if the station is idle.
2. If the station is idle, issue the test port UUCSSpp
command for this port.
3. If the test continues to fail, issue the busy port UUCSSpp
and the release port UUCSSpp commands, and then
retest.
4. If the test still fails, replace the board.
PASS The port can correctly conference multiple connections.
Investigate user-reported troubles on this port by running other
port tests; by examining station, trunk, or external wiring; or by
inspecting the station.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This result could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to make sure that the board translations are
correct. Use the list configuration command, and
resolve any problems.
2. If the board is correctly inserted, issue the busy board
UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This
re-establishes the link between the internal ID and the
port.
6. If this is not the case, check to make sure that a valid
board is inserted.
Table 10-39. TEST #7 Conference Circuit Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page